MRA Micro Gear Pumps offer solutions for the working situation of 1ml-2000 ml/min flow, 0.5-25bar pressure difference and 0.4-3000m.Pas viscosity (similar to water).The pump can withstand a pressure of 4 MPa.
- Flow range: 0.001-48.5 l/m
- Inlet pressure: -0.9-10 bar
- Pressure difference: 0-25.5 bar (depends on material viscosity)
- Temperature: -20-160 (other temperature customized)
- Viscosity range: 0.4-3000 cps
- Max. gravity: 1.8
- Motor options: AC motor, Brushless DC motor, Servo motor, Inverter explosion-proof motor
- Inlet & outlet thread: NPT1/8", 1/4", 3/8", 1/2", 3/4"
- Non-standard customize: OEM machine ancillary, and servo system.
Secure Features & Advantages
Explosive view:
Features:
- Pulsation-free precise converying - Positive displacement pump provide continuous precise conveying through the gears, converying accuracy can reach +/-0.5% with the servo or stepper motor.
- Strong vacuum suction, high pressure and smooth delivery, help to realize the low viscosity liquid delivery in middle & high pressure.
- Zero leakage - Magnetic drive and static O-ring ensure the inside pump medium isolated from the outside.
- Excellent workmanship and MD - The designs optimize the gear shaft, pump body flow channel, and make it longer service life. We have lean manufacturing idea and adopt advanced processing technology & exquisite workmanship. It is an external gearing pump designed & manufactured for high-end application.
- Model selection specialization - We have rich operating experience in thousands of micro gear pump, accumulate lots of experiment data, specialize in selection evaluation, and formulate solution to reduce risks for you.
Advantages:
- Wide displacement range: 0.18ml/r-17ml/r(Meet the request of most micro flow).
- High pressure differential: 10-25.5 bar(Normal), maximum 4Mpa.
- Long service life: Gear& shaft adopt reinforced PEEK gears + high strength nano ceramic shafts combination, which are more wear resistant and greatly improved the service life of the pump. High gear consistency and interchangeability: Processed by Japanese precision CNC hobbling machine, gear consistency and interchangeability is high.
- Temperature range: -120ºC to 180ºC, we use high-performance magnetic material, improve inner magnet over molding process, completely solve the problem of high temperature thermal expansion and bulging.
- High wear-resistance: By the use of high quality bearing grade PEEK modified material (confidential formula), relevant data is available. Wear resistance is ☆☆☆☆☆ by using of nano-ceramic shaft while using SS316L is ☆, and ceramic is ☆☆.
- Long time operated under 100ºC ambient temperature.
- Strong ability of industry application and accurate pump selection data analysis by software instead of experience only.
- Comprehensive testing ability for all elements and the testing result is traceable in the systems.
- High Gear accuracy testing capability by the German Winzer Gear Testing device.
- Service life: >20000 hours while others normally 6000-8000 hours.
Pharmaceutical Industry
Mechanical seal flushing
Precision measurement
Inkject Printing
Lithium Battery
Environmental water treatment
Medical Dialysis
Fine chemical Industry
SCR Tail gas treatment
Pump |
Motor speed(rpm) |
Order No. |
Size |
750 |
960 |
1450 |
2850 |
3300 |
MRA5/13 |
1/8 |
0.150 |
0.192 |
0.290 |
0.570 |
0.660 |
MRA7/13 |
0.293 |
0.374 |
0.566 |
1.112 |
1.287 |
MRA10/13 |
0.450 |
0.576 |
0.870 |
1.710 |
1.980 |
MRA12/13 |
0.525 |
0.672 |
1.015 |
1.995 |
2.310 |
MRB10/16 |
1/4 |
0.750 |
0.960 |
1.450 |
2.850 |
3.300 |
MRB12/16 |
0.900 |
1.152 |
1.740 |
3.420 |
3.960 |
MRB17/16 |
1.275 |
1.632 |
2.465 |
4.845 |
5.610 |
MRB19/16 |
1.425 |
1.824 |
2.755 |
5.415 |
6.270 |
MRC15/22 |
3/8 |
1.800 |
2.304 |
3.480 |
6.840 |
|
MRC20/22 |
2.625 |
3.360 |
5.075 |
9.975 |
|
MRC8/37 |
3.000 |
3.840 |
5.800 |
11.400 |
|
MRC12/37 |
4.500 |
5.760 |
8.700 |
17.100 |
|
MRD25/30 |
1/2 |
5.250 |
6.720 |
10.150 |
19.950 |
|
MRE18/37 |
3/4 |
6.750 |
8.640 |
13.050 |
25.650 |
|
MRE24/37 |
9.000 |
11.520 |
17.400 |
34.200 |
|
MRE34/37 |
12.750 |
16.320 |
24.650 |
48.450 |
|
Theoretical flow(L/min)
OUR SERVICE
FAQ
PART ONE - ABOUT TRADING
Q: Are you a manufacturer of trading company?
A: We are a professional manufacturer engaged in the research and development, production and sales of precision gear pumps.
Our product has passed the test.
The factory has passed the ISO9001-2015 quality system certification of Germany Rheinland and the on-site verification of SGS, the products have passed the CE and ROSH certification, and obtained the certification of several classification societies.
Q: What's your MOQ?
A: There is no MOQ requirement, but the price will be gradient adjusted according to the MOQ size.
Q: How can I get free sample?
A: Free samples are available for some products.
To obtain the free samples, customers need to provide relevant product application scenario video, developed equipment pictures, installation location structure 3D drawing, the progress of the new project (the information provided by the company will be strictly confidential), free samples need to pay logistics costs.
Q: What's your lead time?
A:
1. We have enough stock for conventional pump head, it can be send in 3 days, special non-standard pump head takes 15-20 days
2. Some ABB motors/Delta servo/stepper motors/brushless motors are in stock, please consult our sales engineers.
Q: What is your warranty and after-sales service policy?
A: Warranty for all products is 12 months from delivery, if the warranty period of the pump failure, you can contact our sales engineers, send the pump back to the factory testing, we will take photos, issue inspection report and quote for related parts costs.
Q: Can you provide OEM/ODM service for your products?
A: Yes
Q: What's your payment term?
A: 1. We accept 30% advance payment upon order, balance before delivery.
2.If the pump can be send in 7 days, better 100% upon order.
3.We accept T/T, order on Made-in-China platform, others canbe negoitated according to actual situation.
Q: Do you offer spare kits for your pump?
A: Yes, we have enough spare kits for each pump, if you need to change, send the series number / pump code on the pump, we will send you corresponding spare kits.
Q: How can I choose the model and get the quotation?
A: You just send the working condition for the pump you request, we will choose the proper model and work out technical sheet and official quotation for you to analyze.
PART TWO - ABOUT PUMP TECHNICAL
Q: How is the service life of your gear pump?
A: The normal service life of the micro gear pump can reach more than 25,000 hours.
Below are the source of longevity data:
1. Through working condition simulation verification,
2. Customers'feedback statistics table,
3. Statistical table of maintenance records of the after-sales service department.
Q: What are the wearing parts of the gear pump, and how to solve the problem?
A: The wearing parts mainly include: driving gear shaft, driven gear shaft, bearing, inner magnetic drive, PTFE sealing ring.
Pumps are dynamic equipment, and it is inevitable to encounter various challenges in extreme working conditions, wear and tear of wearing parts, and expiration of the warranty period.
In order to ensure your stable production, for key process control pumps, it is recommended to prepare a plan for running and stand by. If the design space or the budget is insufficient, it is recommended to purchase a set of vulnerable spare parts as an emergency backup plan.
Our precision-grade micro gear pumps feature a two-stage modular design for quick and easy replacement of wearing parts.
You will enjoy the following services:
-Reliable original spare parts kit
-Efficient logistics global distribution
-Relevant technical support to help you choose suitable spare parts (spare parts consultation)
-Professional selection service (selection consultation)
Customers who purchase JONSN precision micro gear pump spare parts, you need to provide the gear pump code (as shown in the picture), we can check the gear fit clearance according to the code, and carry out customized production and processing to ensure consistency.
Q: What is the range of temperature resistance, pressure resistance and differential pressure?
A: Conventional pump heads are resistant to temperatures from -20°C to 80°C, and can be customized for low temperatures of -60°C and high temperatures of 160°C.
The conventional pump head system has a pressure resistance of 4MPa, and some pump head systems have a pressure resistance of 6MPa.
The pressure difference between the inlet and outlet is more than 25bar (depending on the viscosity)
Q: What factors should be considered in the installation of the pump? What should be considered when designing the piping system of the pump?
A: When designing, the pump is best installed under the tank, the motor base is locked with screws, and the positive pressure of the medium is input to the pump inlet, especially for the viscous medium, which has poor fluidity. Due to the small size of the micro gear pump, avoid piping or instrumentation pressing against the pump body.
The inlet pipe is as short as possible, and the inlet pipe shoube be equipped with a filter to keep the pipe clean and free of particles.
Pipe diameter requirements: For conveying viscous media, it is recommended that the pipe be larger than the pump inlet size. It should be used according to the pipe diameter recommended by our company's selection software. Sometimes the inlet is too small to meet the flow requirements.
Q: What chemicals can the micro gear pump transport?
A: Our pumps are available in different materials and a compatible material can be found for most fluids. Due to the wide variety of working conditions and fluids, we always recommend in any case to first test the pump in the circuit under the same conditions as it will actually run. If the material you transport contains dichloromethane, tetrahydrofuran, nitric acid, sulfuric acid, butyllithium, trimethylgallium, pyridine, liquid chlorine, dimethylacetamide and other media, please contact us, if conventional pump head cannot transport this media, we can make customized solutions according to the working conditions.
Q: Can the pump be used for metering?
A: All of our pumps are positive displacement pumps for metering applications. Accuracy and repeatability will depend on the pump driver/control system used and the nature of the fluid, delivery accuracy can be +/-0.5%. Please contact us for details.
Q: Which motors can be used?
A: We offer a range of different drive types including DC Brushless, DC Brush, AC Inverter, Servo, Stepper Motor, Air Motor.
Q: How can we decide the input power of the pump?
A: JONSN can calculate the required input power according to your working requirements and fluid characteristics.
Q: What is the noise value of the pump?
A: Noise levels depend on pump installation, motor speed and fluid type. The gear pump has a reference value of 55 dB at 1 meter when the pressure difference is 3 bar and the speed is 3000 rpm.
Q: Can liquids containing solid particles be transported?
A: Gear pumps cannot transport media with particles.
Q: Can the pump be reversed?
A: Preferably the direction of the arrow is marked at the factory as the standard flow direction, but both directions can be run.
Q: Can the pump run dry?
A: Our gears and bushings are made of PEEK modified and post-treated, which has a strong ability to resist dry wear. You can view our dry run test video. However, dry running should be minimized to avoid shortening pump life.
Q: Is the pump self-priming?
A: Yes, please refer to our datasheet.
Q: What is the operating temperature of the pump and motor?
A: Our conventional pump heads can operate normally at a temperature of -20 ~ 80°C. Please consult us if the temperature exceeds 80°C or other temperatures, factors such as magnets, clearances, and motor bearings need to be considered.
Q: How does viscosity affect gear pump and system performance?
A: Viscous materials can increase the volumetric efficiency of the pump and reduce the leakage of the gear pump. However, depending on the viscosity, the speed needs to be reduced to prevent overloading. Low-viscosity fluid will lead to greater internal leakage. As the outlet pressure increases, the internal leakage increases and and the volumetric efficiency decreases. When the pressure, speed, and medium temperature remain constant, the internal leakage rate will remain constant, and the flow rate will remain linear relationship. Please consult factory for details.
Q: What happens when a gas and liquid mixture is pumped through a gear pump?
A: The gas/liquid mixture will pass through the pump without any problems. The pump may appear noisier when gas is passing through. There will also be a momentary change in the load on the pump, which can be seen by fluctuations in the outlet pressure and power consumed by the motor.
Q: What are the minimum and maximum speeds allowed?
A: The data sheet for each model states the maximum speed, but these parameters are based on the water as medium. For viscous fluids, the maximum speed needs to be reduced. The minimum speed is mainly determined by the motor starting speed control, flow rate and internal leakage factors.
Q: Are Micro Gear Pumps FDA Approved?
A: Pumps are available with FDA compliant materials.
Q: What is the recommended filtering level?
A: It is recommended to install a 25 micron filter at the inlet of the pump with a filter surface large enough to avoid pressure drop and protect the internal parts of the pump.
Q: What affects pump and motor life?
A: Many factors affect service life. The key issues to consider are the number of on/off cycles, operating speed, load (pressure) and fluid contamination.
Q: What is decoupling (aka demagnetization)? Can this be used as a safety feature?
A: If the load of the pump and the torque capacity of the motor exceed the torque capacity of the magnetic coupling, the magnetic drive pump will become decoupled and will be noisy. When decoupling occurs, the motor should stop immediately for troubleshooting.
Q: How do we adjust flow rate?
A: For positive displacement pumps, the easiest way to adjust the flow is to adjust the motor speed. There is an almost linear relationship between speed and flow.
Q: What is the starting capacity of the micro gear pump?
A: Starting capability varies from pump to pump and depends on a number of factors including fluid viscosity, line size, steam pressure, speed and whether the pump is running wet or dry.
Q: What is internal leakage of gear pump?
A:The internal leakage of the gear pump means that part of the fluid on the pressure side flows back to the inlet side through the gear gap, which affects the efficiency. Internal leakage is a common problem for all gear pumps. The internal leakage of precision micro gear pumps will be relatively small, and low-viscosity fluids can pass through these small gaps more easily, so the pump is more efficient in thicker or more viscous fluids.
Q: What is cavitation?
A: Cavitation is the formation of vapor cavities ("bubbles" or "voids") in the liquid - a result of the inlet pipe diameter being smaller than the pump's flow rate. These cavities are formed by the fluid and physical properties of the pump system (available pressure, temperature, pump speed...). Cavitation is prone to noise and premature pump wear.
Q: How do I identify Jonsn pump?
A: Each pump has LOGO and laser code identification on the end face. They all identify the date of manufacture, product code and serial number (S/N). The original configuration sheet and test records can be traced through the S/N code.
Congratulations, you read all listed information about gear pump, you are quite professional in pumps!