Magnetic High Accuracy Dialysate Pump Long Working Time

Product Details
Customization: Available
After-sales Service: 1 Year Warranty
Warranty: 1 Year Warranty
Still deciding? Get samples of US$ 500/Piece
Request Sample
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (26)
  • Magnetic High Accuracy Dialysate Pump Long Working Time
  • Magnetic High Accuracy Dialysate Pump Long Working Time
  • Magnetic High Accuracy Dialysate Pump Long Working Time
  • Magnetic High Accuracy Dialysate Pump Long Working Time
  • Magnetic High Accuracy Dialysate Pump Long Working Time
  • Magnetic High Accuracy Dialysate Pump Long Working Time
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Secure Features & Advantages
  • Applications
  • Product Diagram
  • Theroetical Flow Rate
  • Performance Curve
  • ABOUT JONSN
Overview

Basic Info.

Model NO.
MRA5/13
Mesh Form
Internal Engaged
Tooth Flank
Straight Tooth
Tooth Curve
Involute
Power
Electric
Type
Arc Gear Pump
Applications
Machinery Manufacturing
Certification
CE, ISO
Model
Mra5/13
Flow Rate
0.15-0.66L/Min
Viscosity
0.4-3000 Cps
Pressure Differential
0-25.5 Bar
Max. Temperature
-40 to 180 ºC
Pump Body Material
SS316L/Alloy C
Gear
Reinforced Peek
Shaft
Nano-Ceramic
Certificate
CE, ISO9001, Nk, BV, ABS, RoHS
Motor
AC, BLDC, Servo, Inverter, Ex-Proof Motor
Capacity
5000 Sets
Transport Package
Plywood Case
Trademark
JONSN
Origin
Ganzhou, China
Production Capacity
5000

Product Description

Magnetic High Accuracy Dialysate Pump Long Working Time
Product Description
 
Magnetic High Accuracy Dialysate Pump Long Working Time
Introducing Jonsn (Ganzhou) Fluid Technology Co., Ltd.'s Magnetic High Pressure Dialysate Pump, an engineering marvel designed to effortlessly handle fluid working conditions. This innovative series efficiently manages flows ranging from 0.15 to 2.3 L/min, pressure differences between 0.5 and 25 bar, and viscosities from 0.4 to 3000 m.Pas, akin to that of water. Moreover, this robust pump can endure pressures up to an impressive 4 MPa, ensuring reliability and performance in demanding environments.
 
WORKING PRINCIPLE
 
Magnetic High Accuracy Dialysate Pump Long Working Time
Product Parameters
 
  • Impressive Flow Range: 0.001 - 48.5 liters per minute
  • Robust Inlet Pressure: From -0.9 to 10 bars
  • Versatile Pressure Difference: 0 to 25.5 bars (Material viscosity dependent)
  • Adaptable Temperature Range: -20 to 160 degrees Celsius (Customizable for other temperatures)
  • Broad Viscosity Range: 0.4 to 3000 cps
  • Maximum Gravity: Up to 1.8
  • Diverse Motor Options: AC motor, Brushless DC motor, Servo motor, Inverter explosion-proof motor
  • Customizable Inlet & Outlet Threads: NPT1/8", 1/4", 3/8", 1/2", 3/4"
  • Tailored Solutions: OEM machine ancillary and servo system customization available
Secure Features & Advantages
 
Detailed Explosive View:
Magnetic High Accuracy Dialysate Pump Long Working Time
Key Features:
  1. Pulse-Free, Precision Conveying - Our Positive displacement pumps ensure continuous, precise conveying through advanced gears. Achieve conveying accuracy of +/-0.5% with the precision of servo or stepper motors.
  2. Robust Vacuum Suction, High Pressure, and Smooth Delivery - Facilitates low viscosity liquid delivery in medium to high-pressure settings.
  3. Absolute Zero Leakage - Magnetic drive and static O-ring design ensure the pumped medium remains completely isolated from the external environment.
  4. Exquisite Workmanship and Design - Optimized gear shaft and pump body flow channel, ensuring extended service life. Embracing lean manufacturing and advanced processing technology, our external gearing pump meets high-end application demands with precision.
  5. Specialized Model Selection - Leverage our rich experience from thousands of micro gear pumps. Utilize extensive experimental data to specialize in selection evaluation, providing solutions that mitigate risks efficiently.

Remarkable Advantages:
  • Versatile Displacement Range - 0.18ml/r to 17ml/r. Meets the diverse needs of most micro flow applications.
  • Exceptional Pressure Differential - Standard range from 10-25.5 bar, with a maximum of 4Mpa.
  • Extended Service Life - Utilizing reinforced PEEK gears paired with high-strength nano-ceramic shafts, our pumps offer superior wear resistance and significantly prolonged operational lifespan. Superior Gear Consistency and Interchangeability - Precision-processed with Japanese CNC hobbling machines, ensuring high consistency and interchangeability.
  • Wide Temperature Range - From -120ºC to 180ºC. Using high-performance magnetic materials and improved inner magnet molding processes, we eliminate issues related to high-temperature expansion.
  • Exceptional Wear-Resistance - High-quality bearing-grade PEEK modified material (proprietary formula) ensures top-tier wear resistance. Relevant data available upon request.☆☆☆☆☆ - With nano-ceramic shafts, while SS316L scores and ceramic scores ☆☆.
  • Durable Operation Under High Temperatures
  • Strong Industrial Application and Accurate Pump Selection Data Analysis - Achieved through software-driven methods rather than solely relying on experience.
  • Comprehensive Testing Capabilities - All elements undergo rigorous testing with results being traceable in our systems.
  • High Gear Accuracy Testing - Conducted using the German Winzer Gear Testing device for unparalleled precision.
  • Extended Service Life - Exceeding 20,000 hours, compared to the typical 6,000-8,000 hours of others.
Applications

Magnetic High Accuracy Dialysate Pump Long Working Time
Product Diagram

Magnetic High Accuracy Dialysate Pump Long Working Time
Theroetical Flow Rate
 
Pump Motor speed(rpm)
Order No. Size 750 960 1450 2850 3300
MRA5/13 1/8 0.150 0.192 0.290 0.570 0.660
MRA7/13 0.293 0.374 0.566 1.112 1.287
MRA10/13 0.450 0.576 0.870 1.710 1.980
MRA12/13 0.525 0.672 1.015 1.995 2.310
MRB10/16 1/4 0.750 0.960 1.450 2.850 3.300
MRB12/16 0.900 1.152 1.740 3.420 3.960
MRB17/16 1.275 1.632 2.465 4.845 5.610
MRB19/16 1.425 1.824 2.755 5.415 6.270
MRC15/22 3/8 1.800 2.304 3.480 6.840  
MRC20/22 2.625 3.360 5.075 9.975  
MRC8/37 3.000 3.840 5.800 11.400  
MRC12/37 4.500 5.760 8.700 17.100  
MRD25/30 1/2 5.250 6.720 10.150 19.950  
MRE18/37 3/4 6.750 8.640 13.050 25.650  
MRE24/37 9.000 11.520 17.400 34.200  
MRE34/37 12.750 16.320 24.650 48.450  
 

Theoretical Flow (L/min)

Performance Curve

Magnetic High Accuracy Dialysate Pump Long Working Time
OUR SERVICE: At Jonsn (Ganzhou) Fluid Technology Co., Ltd., we pride ourselves on delivering exceptional service that complements our top-tier products like the Magnetic High Pressure Dialysate Pump. Our dedicated team is committed to providing comprehensive support, ensuring your needs are met with precision and care. From initial consultation to after-sales assistance, we are here to guide you every step of the way, ensuring seamless integration and optimal performance of our innovative fluid technology solutions.
Magnetic High Accuracy Dialysate Pump Long Working Time
ABOUT JONSN

Magnetic High Accuracy Dialysate Pump Long Working TimeMagnetic High Accuracy Dialysate Pump Long Working TimeMagnetic High Accuracy Dialysate Pump Long Working TimeMagnetic High Accuracy Dialysate Pump Long Working Time
FAQ
PART ONE - ABOUT TRADING

Q: Are you a manufacturer of trading company?
A: We are a professional manufacturer engaged in the research and development, production and sales of precision gear pumps.
Our product has passed the test.

Our factory boasts an esteemed ISO9001-2015 quality system certification accredited by Germany Rheinland, complementing the on-site verification by SGS. Our products proudly bear the CE and ROSH certifications and have been endorsed by multiple classification societies.

Q: What's your MOQ?
A: There is no official MOQ requirement; however, pricing will be adjusted on a gradient scale based on the size of the order.

Q: How can I get free sample?
A: Free samples are available for some products.
 Free samples are available for select products.
To qualify for free samples, customers must provide a video of the product application scenario, images of the developed equipment, a 3D drawing of the installation location structure, and progress details of the new project. All provided information will be kept strictly confidential. Please note that logistics costs for free samples will need to be covered by the customer.

Q: What's your lead time?
A:
1. 
 For conventional pump heads, we maintain sufficient stock and can dispatch within 3 days. Custom, non-standard pump heads require a lead time of 15-20 days.
2. We stock a range of motors, including branded AC motors, Delta servo/stepper motors, and brushless motors. For availability, please consult our sales engineers.

Q: What is your warranty and after-sales service policy?
A: All our products come with a 12-month warranty from the date of delivery. Should any issues arise within the warranty period, please contact our sales engineers. Return the pump for factory testing, and we will provide photos, an inspection report, and a quote for any necessary parts.

Q: Can you provide OEM/ODM service for your products?
A: Yes, we offer OEM/ODM services.

Q: What's your payment term?
A: 1. We accept a 30% advance payment upon order placement, with the balance due before delivery.
2. For pumps that can be dispatched within 7 days, a full 100% payment upon order is preferable.
3. We accept T/T, orders on the Made-in-China platform, and other terms can be negotiated based on the specific situation.

Q: Do you offer spare kits for your pump?
A: Yes, we maintain ample spare kits for each pump model. Simply provide the series number/pump code, and we will send the corresponding spare kits.

Q: How can I choose the model and get the quotation?
A: Provide the working conditions for the pump you require, and we will select the appropriate model and prepare a technical sheet along with an official quotation for your analysis..

PART TWO - ABOUT PUMP TECHNICAL

Q: How is the service life of your gear pump?
A: The typical service life of our micro gear pump exceeds 25,000 hours.
Below are thesources of longevity data:
1. Verified through working condition simulations.
2. Feedback from customers.
3. Maintenance records from the after-sales service department.

Q: What are the wearing parts of the gear pump, and how to solve the problem?
A: The wearing parts mainly include: driving gear shaft, driven gear shaft, bearing, inner magnetic drive, PTFE sealing ring.
Pumps are dynamic equipment, and it is inevitable to encounter various challenges in extreme working conditions, wear and tear of wearing parts, and expiration of the warranty period.

In order to ensure your stable production, for key process control pumps, it is recommended to prepare a plan for running and stand by. If the design space or the budget is insufficient, it is recommended to purchase a set of vulnerable spare parts as an emergency backup plan.
Our precision-grade micro gear pumps feature a two-stage modular design for quick and easy replacement of wearing parts.
You will enjoy the following services:
-Reliable original spare parts kit
-Efficient logistics global distribution
-Relevant technical support to help you choose suitable spare parts (spare parts consultation)
-Professional selection service (selection consultation)

Customers who purchase JONSN precision micro gear pump spare parts, you need to provide the gear pump code (as shown in the picture), we can check the gear fit clearance according to the code, and carry out customized production and processing to ensure consistency.

Q: What is the range of temperature resistance, pressure resistance and differential pressure?
A: Conventional pump heads are resistant to temperatures from -20°C to 80°C, and can be customized for low temperatures of -60°C and high temperatures of 160°C.
The conventional pump head system has a pressure resistance of 4MPa, and some pump head systems have a pressure resistance of 6MPa.
The pressure difference between the inlet and outlet is more than 25bar (depending on the viscosity)


Q: What factors should be considered in the installation of the pump? What should be considered when designing the piping system of the pump?
A: When designing, the pump is best installed under the tank, the motor base is locked with screws, and the positive pressure of the medium is input to the pump inlet, especially for the viscous medium, which has poor fluidity. Due to the small size of the micro gear pump, avoid piping or instrumentation pressing against the pump body.

The inlet pipe is as short as possible, and the inlet pipe 
shoube be equipped with a filter to keep the pipe clean and free of particles.

Pipe diameter requirements: For conveying viscous media, it is recommended that the pipe be larger than the pump inlet size. It should be used according to the pipe diameter recommended by our company's selection software. Sometimes the inlet is too small to meet the flow requirements.



Q: What chemicals can the micro gear pump transport?
A: Our pumps are available in different materials and a compatible material can be found for most fluids. Due to the wide variety of working conditions and fluids, we always recommend in any case to first test the pump in the circuit under the same conditions as it will actually run. If the material you transport contains dichloromethane, tetrahydrofuran, nitric acid, sulfuric acid, butyllithium, trimethylgallium, pyridine, liquid chlorine, dimethylacetamide and other media, please contact us, if conventional pump head cannot transport this media, we can make customized solutions according to the working conditions.

Q: Can the pump be used for metering?
A: All of our pumps are positive displacement pumps for metering applications. Accuracy and repeatability will depend on the pump driver/control system used and the nature of the fluid, delivery accuracy can be +/-0.5%. Please contact us for details.

Q: Which motors can be used?
A: We offer a range of different drive types including DC Brushless, DC Brush, AC Inverter, Servo, Stepper Motor, Air Motor.

Q: How can we decide the input power of the pump?
A: JONSN can calculate the required input power according to your working requirements and fluid characteristics.


Q: What is the noise value of the pump?
A: Noise levels depend on pump installation, motor speed and fluid type. The gear pump has a reference value of 55 dB at 1 meter when the pressure difference is 3 bar and the speed is 3000 rpm.

Q: Can liquids containing solid particles be transported?
A: Gear pumps cannot transport media with particles.

Q: Can the pump be reversed?
A: Preferably the direction of the arrow is marked at the factory as the standard flow direction, but both directions can be run.

Q: Can the pump run dry?
A: Our gears and bushings are made of PEEK modified and post-treated, which has a strong ability to resist dry wear. You can view our dry run test video. However, dry running should be minimized to avoid shortening pump life.

Q: Is the pump self-priming?
A: Yes, please refer to our datasheet.

Q: What is the operating temperature of the pump and motor?
A: Our conventional pump heads can operate normally at a temperature of -20 ~ 80°C. Please consult us if the temperature exceeds 80°C or other temperatures, factors such as magnets, clearances, and motor bearings need to be considered.

Q: How does viscosity affect gear pump and system performance?
A: Viscous materials can increase the volumetric efficiency of the pump and reduce the leakage of the gear pump. However, depending on the viscosity, the speed needs to be reduced to prevent overloading. Low-viscosity fluid will lead to greater internal leakage. As the outlet pressure increases, the internal leakage increases and and the volumetric efficiency decreases. When the pressure, speed, and medium temperature remain constant, the internal leakage rate will remain constant, and the flow rate will remain linear relationship. Please consult factory for details.

Q: What happens when a gas and liquid mixture is pumped through a gear pump?
A: The gas/liquid mixture will pass through the pump without any problems. The pump may appear noisier when gas is passing through. There will also be a momentary change in the load on the pump, which can be seen by fluctuations in the outlet pressure and power consumed by the motor.

Q: What are the minimum and maximum speeds allowed?
A: The data sheet for each model states the maximum speed, but these parameters are based on the water as medium. For viscous fluids, the maximum speed needs to be reduced. The minimum speed is mainly determined by the motor starting speed control, flow rate and internal leakage factors.

Q: Are Micro Gear Pumps FDA Approved?
A: Pumps are available with FDA compliant materials.

Q: What is the recommended filtering level?
A: It is recommended to install a 25 micron filter at the inlet of the pump with a filter surface large enough to avoid pressure drop and protect the internal parts of the pump.

Q: What affects pump and motor life?
A: Many factors affect service life. The key issues to consider are the number of on/off cycles, operating speed, load (pressure) and fluid contamination.

Q: What is decoupling (aka demagnetization)? Can this be used as a safety feature?
A: If the load of the pump and the torque capacity of the motor exceed the torque capacity of the magnetic coupling, the magnetic drive pump will become decoupled and will be noisy. When decoupling occurs, the motor should stop immediately for troubleshooting.

Q: How do we adjust flow rate?
A: For positive displacement pumps, the easiest way to adjust the flow is to adjust the motor speed. There is an almost linear relationship between speed and flow.

Q: What is the starting capacity of the micro gear pump?

A: Starting capability varies from pump to pump and depends on a number of factors including fluid viscosity, line size, steam pressure, speed and whether the pump is running wet or dry.

Q: What is internal leakage of gear pump?
A:The internal leakage of the gear pump means that part of the fluid on the pressure side flows back to the inlet side through the gear gap, which affects the efficiency. Internal leakage is a common problem for all gear pumps. The internal leakage of precision micro gear pumps will be relatively small, and low-viscosity fluids can pass through these small gaps more easily, so the pump is more efficient in thicker or more viscous fluids.

Q: What is cavitation?
A: Cavitation is the formation of vapor cavities ("bubbles" or "voids") in the liquid - a result of the inlet pipe diameter being smaller than the pump's flow rate. These cavities are formed by the fluid and physical properties of the pump system (available pressure, temperature, pump speed...). Cavitation is prone to noise and premature pump wear.

Q: How do I identify Jonsn pump?
A: Each pump has LOGO and laser code identification on the end face. They all identify the date of manufacture, product code and serial number (S/N). The original configuration sheet and test records can be traced through the S/N code.

Congratulations, you've absorbed all the essential information about gear pumps, showcasing your expertise in this domain!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now